Performance of multilayer glass and BIPV façade structures : [chapter] 9Medved, Sašo ...The object of the research described in this chapter is evaluation of the thermal response of advanced glass façade structures with improved energy performance during cooling of the building. Two ... types of glazed façade structures were analyzed: a six-pane glazing structure upgraded with a building integrated photovoltaic (BIPV) system with and without phase change material (PCM) inserts, and a BIPV double-glazed façade with transparent triple-glazed interior structure. Such façade structures are particularly relevant for nonresidential buildings and for all-glass-façade buildings, whether new or refurbished. The diurnal transient thermal response of constructions under investigation was evaluated using a computational fluid dynamics technique for extreme daily summer climate conditions for Athens, Ljubljana, and Stockholm. Validation of the numerical modeling is given for the BIPV glazed façade with and without PCM inserts. A parametric study on position and melting point temperature as well as ventilation intensity was carried out. Energy performance indicators were developed to evaluate the cooling load and potential of increased efficiency of electricity production using PV cells.Source: Eco-efficient materials for reducing cooling needs in buildings and construction : design, properties and applications (Str. 169-202)Type of material - article, component partPublish date - 2021Language - englishCOBISS.SI-ID - 35401475
Author
Medved, Sašo |
Arkar, Ciril |
Domjan, Suzana |
Žižak, Tej
Topics
multilayer glass façade structures |
optimisation |
overheating hours |
BIPV |
večslojni stekleni fasadni sistemi |
PCM |
optimizacija |
ure pregrevanja
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
| Year | Impact factor | Edition | Category | Classification | ||||
|---|---|---|---|---|---|---|---|---|
| JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP | |
Impact factor
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
| Database name | Field | Year |
|---|
| Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
|---|---|
| Medved, Sašo | 03408 |
| Arkar, Ciril | 11809 |
| Domjan, Suzana | 30588 |
| Žižak, Tej | 55031 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
| Pickup location | Material status | Reservation |
|---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: