Theoretical and experimental investigations of flow pulsation effects in Coriolis mass flowmetersSvete, Andrej, 1983- ...An understanding of the effects of flow pulsations on the dynamic behavior of Coriolis flowmeters is very important for their further development. In order to determine the phase difference between ... the vibrational signals, which represents the basic measurement effect of Coriolis flowmeters, there are many methods that include the proper filtering of all the signal components, except those with frequencies close to the drive frequency. Therefore, an understanding of the phenomenon of exciting the meter at its first natural frequency is very important. The results of a simple, linear, two-degree-of-freedom, lumped-parameter, dynamic model of a flowmeter show that the flow pulsations can degrade the accuracy of such a flowmeter as a result of indirect excitations of the measuring tube at the first natural frequency through the second-order perturbations by means of the Coriolis forces induced in pulsating flow conditions. In order to experimentally investigate these flow pulsation effects, a prototype of a straight-tube Coriolis mass flowmeter was developed to enable the processing of the response signals logged directly from the flow tubeʼs sensors with the dual quadrature demodulation method, and therefore to provide the information available within the phase-difference data. The experimental results show that the flow pulsations upset the meter at its first natural frequency indirectly, as well as directly at the frequency of the pulsations due to the geometric imperfections of the measuring tube.Source: Journal of sound and vibration. - ISSN 0022-460X (Vol. 352, Sep. 2015, str. 30-45)Type of material - article, component partPublish date - 2015Language - englishCOBISS.SI-ID - 14007579
Author
Svete, Andrej, 1983- |
Kutin, Jože |
Bobovnik, Gregor, 1978- |
Bajsič, Ivan
Topics
Coriolis flowmeters |
flow pulsation |
pulsating flow |
pulsation effect |
phase-difference |
demodulation method |
merjenje toka |
Coriolisovi merilniki pretoka |
tokovna pulzacija |
pulzacija toka |
učinek pulzacije |
fazna razlika |
metoda demodulacije
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
| Year | Impact factor | Edition | Category | Classification | ||||
|---|---|---|---|---|---|---|---|---|
| JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP | |
Impact factor
Select the library membership card:
DRS, in which the journal is indexed
| Database name | Field | Year |
|---|
| Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
|---|---|
| Svete, Andrej, 1983- | 29619 |
| Kutin, Jože | 20047 |
| Bobovnik, Gregor, 1978- | 22455 |
| Bajsič, Ivan | 03562 |
Select pickup location:
Material pickup by post
Notification
Subject headings in COBISS General List of Subject Headings
Select pickup location
| Pickup location | Material status | Reservation |
|---|
Please wait a moment.