ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patientsCaroli, Anna ...Vascular access dysfunction is one of the main causes of morbidity and hospitalization in hemodialysis patients. This major clinical problem points out the need for prediction of hemodynamic changes ... induced by vascular access surgery. Here we reviewed the potential of a patient-specific computational vascular network model that includes vessel wall remodeling to predict blood flow change within 6 weeks after surgery for different arteriovenous fistula configurations. For model validation, we performed a multicenter, prospective clinical study to collect longitudinal data on arm vasculature before and after surgery. Sixty-three patients with newly created arteriovenous fistula were included in the validation data set and divided into four groups based onfistula configuration. Predicted brachial artery blood flow volumes 40 days after surgery had a significantly high correlation with measured values. Deviation of predicted from measured brachial artery blood flow averaged 3% with a root mean squared error of 19.5%, showing that the computational tool reliably predicted patient-specific blood flow increase resulting from vascular access surgery and subsequent vascular adaptation. This innovative approach may help the surgeon to plan the most appropriate fistula configuration to optimize access blood flow for hemodialysis, potentially reducing the incidence of vascular access dysfunctions and the need of patienthospitalization.Source: Kidney international. - ISSN 0085-2538 (Vol. 83, no. 6, 2013, str. 1237-1245)Type of material - article, component partPublish date - 2013Language - englishCOBISS.SI-ID - 840620
Author
Caroli, Anna |
Malovrh, Marko
Topics
access blood flow |
hemodialysis access |
vascular access
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
| Year | Impact factor | Edition | Category | Classification | ||||
|---|---|---|---|---|---|---|---|---|
| JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP | |
Impact factor
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
| Database name | Field | Year |
|---|
| Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
|---|---|
| Caroli, Anna | ![]() |
| Malovrh, Marko | 06203 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
| Pickup location | Material status | Reservation |
|---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: