ALL libraries (COBIB.SI union bibliographic/catalogue database)
-
Reliability of in-shoe plantar pressure measurements in rheumatoid arthritis patientsVidmar, Gaj ; Novak, Primož, 1972-Plantar pressures measurement is a frequently used method in rehabilitation and related research. Metric characteristics of the F-Scan system have been assessed from different standpoints and in ... different patients, but not its reliability in rheumatoid arthritis patients. Therefore, our objective was to assess reliability of the F-Scan plantar pressure measurement system in rheumatoid arthritis patients. Twelve rheumatoid arthritis patients were included in this study. Plantar pressures measurement was carried out in six consecutive walks and average peak pressure on seven spots analyzed for each walk. Intraclass correlation was estimated for each spot and for within-patient coefficient of variation between spots. For each spot, average within-patient coefficient of variation between walks was also calculated. Repeated measures of analysis of variance and Hotelling's T2 test, both with Holm correction, were used to test equality of mean measurement across patients between walks. The intraclass correlations, which were all statistically significant at P<0.0001, ranged from 0.897 to 0.999, with a mean of 0.97 for single measure and 0.99 for average measure estimates. Overall median of within-patient coefficient of variation between walks was 7%. None of the tests of equality of means showed significant differences between walks. On both feet, the highest variability of measurements was observed at midfoot, whereas all the other spots demonstrated excellent reliability. The measurement setup was found to be highly reliable and therefore suitable for clinical practice, as well as for research. If possible, taking an average of several measurements is recommended.Source: International journal of rehabilitation research. - ISSN 0342-5282 (Vol. 32, no. 1, 2009, str. 36-40)Type of material - article, component part ; adult, seriousPublish date - 2009Language - englishCOBISS.SI-ID - 893801
Author
Vidmar, Gaj |
Novak, Primož, 1972-
Topics
F-Scan system |
plantar pressure measurement |
reliability |
repeatability |
rheumatoid arthritis
source: International journal of rehabilitation research. - ISSN 0342-5282 (Vol. 32, no. 1, 2009, str. 36-40)
Shelf entry
Permalink
- URL:
Impact factor
Access to the JCR database is permitted only to users from Slovenia. Your current IP address is not on the list of IP addresses with access permission, and authentication with the relevant AAI accout is required.
| Year | Impact factor | Edition | Category | Classification | ||||
|---|---|---|---|---|---|---|---|---|
| JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP | |
Impact factor
Select the library membership card:
If the library membership card is not in the list,
add a new one.
DRS, in which the journal is indexed
| Database name | Field | Year |
|---|
| Links to authors' personal bibliographies | Links to information on researchers in the SICRIS system |
|---|---|
| Vidmar, Gaj | 17837 |
| Novak, Primož, 1972- | 20341 |
Source: Personal bibliographies
and: SICRIS
Select pickup location:
Material pickup by post
Delivery address:
Address is missing from the member's data.
The address retrieval service is currently unavailable, please try again.
By clicking the "OK" button, you will confirm the pickup location selected above and complete the reservation process.
By clicking the "OK" button, you will confirm the above pickup location and delivery address, and complete the reservation process.
By clicking the "OK" button, you will confirm the address selected above and complete the reservation process.
Notification
Automatic login and reservation service currently not available. You can reserve the material on the Biblos portal or try again here later.
Subject headings in COBISS General List of Subject Headings
Select pickup location
The material from the parent unit is free. If the material is delivered to the pickup location from another unit, the library may charge you for this service.
| Pickup location | Material status | Reservation |
|---|
Reservation in progress
Please wait a moment.
Reservation was successful.
Reservation failed.
Reservation...
Membership card:
Pickup location: