-
Electrokinetic properties of commercial vascular graftsIndest, Tea ...The surface morphology and chemical composition (the presence or absence of surface functional groups) of commercial vascular graftsć surfaces are significant for their interaction abilities with ... components of polar liquids. This can also be assumed as correct for grafts-blood interactions. In this paper we studied the adsorption characteristics of different graftsć surfaces using an electrokinetic measurement technique. A comparative study was performed on woven, knitted polyethylene terephthalate (PET) and polytetrafluoroethylene (PTFE) vascular grafts. Streaming potential measurements were used for the determination of zeta potential (Ž), which was studied as a function of electrolyte solutionsć pH and surfactant concentration (using standard cationic surfactants i.e. N-CP-Cl, N-DP-Cl) in order to obtain information about critical charge reversal concentration (CRC). The analysed surface morphology and some physical properties were correlated with the electrokinetic properties of different grafts, and studiedregarding their adsorption characteristics. The SEM images of graft surfaces show that woven PET has more densely packed and more-ordered structure than knitted PET. The PTFE surface exhibits a typical micro-porous structure for a tubular membrane. The strong dependence of zeta potential can be observed from the exposure time to the electrolyte solution. The Ž-pH functions (pH of electrolyte solution) show significant differences between different grafts. Small differences in molecular masses between both surfactants applied cause clear differences in the adsorption behaviours of the arterial grafts.Vir: Colloids and surfaces. A, Physicochemical and Engineering Aspects. - ISSN 0927-7757 (Vol. 275, iss. 1/3, 2006, str. 17-26)Vrsta gradiva - članek, sestavni delLeto - 2006Jezik - angleškiCOBISS.SI-ID - 10025494
Avtor
Indest, Tea |
Strnad, Simona, 1965- |
Stana-Kleinschek, Karin |
Ribitsch, Volker |
Fras Zemljič, Lidija
Teme
tekstilna vlakna |
žilni vsadki |
PET |
PTFE |
površinske lastnosti |
morfologija |
adsorpcija površinsko aktivnih snovi |
elektrokinetične lastnosti |
zeta potencial |
textile fibres |
vascular grafts |
PET |
PTFE |
surface properties |
morphology |
surfactant adsorption |
electrokinetic properties |
zeta potential
Vnos na polico
Trajna povezava
- URL:
Faktor vpliva
Dostop do baze podatkov JCR je dovoljen samo uporabnikom iz Slovenije. Vaš trenutni IP-naslov ni na seznamu dovoljenih za dostop, zato je potrebna avtentikacija z ustreznim računom AAI.
| Leto | Faktor vpliva | Izdaja | Kategorija | Razvrstitev | ||||
|---|---|---|---|---|---|---|---|---|
| JCR | SNIP | JCR | SNIP | JCR | SNIP | JCR | SNIP | |
Faktor vpliva
Baze podatkov, v katerih je revija indeksirana
| Ime baze podatkov | Področje | Leto |
|---|
| Povezave do osebnih bibliografij avtorjev | Povezave do podatkov o raziskovalcih v sistemu SICRIS |
|---|---|
| Indest, Tea | 24334 |
| Strnad, Simona, 1965- | 10575 |
| Stana-Kleinschek, Karin | 07814 |
| Ribitsch, Volker | 15077 |
| Fras Zemljič, Lidija | 19753 |
Izberite prevzemno mesto:
Prevzem gradiva po pošti
Obvestilo
Gesla v Splošnem geslovniku COBISS
Izbira mesta prevzema
| Mesto prevzema | Status gradiva | Rezervacija |
|---|
Prosimo, počakajte trenutek.